Technical

IP Rating Guide

IEC 60529 explained with application mapping.

1. Why it matters

The IP (Ingress Protection) code, defined by IEC 60529, tells you exactly how well a luminaire keeps out solids and water. Two digits carry the whole meaning: the first is protection against solid objects and dust (0-6), the second against water (0-9). Reading it correctly stops you from over-paying for sealing you do not need, or — far worse — installing an indoor-rated fixture where rain or wash-down will kill it.

First digit = dust (aim IP6X outdoors), second digit = water; match the second digit to the real exposure, not the marketing.

2. What each digit means

2nd digitProtection against waterTypical use
4Splashing from any directionCovered outdoor, bathrooms
5Low-pressure jetsWash-down light duty
6Powerful jetsShip decks, wash-down
7Immersion to 1 m, 30 minIn-ground, temporary flood
8Continuous immersion (agreed depth)Fountains, underwater

3. Choose the rating by real exposure

Match the second digit to what the fixture will actually face, then add margin for cleaning and weather. A common, costly mistake is specifying by the room name rather than the exposure — a "warehouse" high bay over a food line that gets pressure-washed needs IP65/IP66, not the IP20 that "indoor" implies.

  • Indoor dry (office, dry warehouse): IP20 is enough.
  • Damp/covered outdoor (canopy, eaves): IP54-IP65.
  • Exposed outdoor, wash-down, marine: IP65-IP66.
  • Submerged (fountain, pool): IP68 with a stated depth.

4. Verify the rating is real and durable

An IP number on a datasheet is a claim; the test report and the design detail are the proof. Ask for the IEC 60529 test report for the exact model, and look at how the seal is achieved — a proper gasket and breather versus a bead of silicone that fails in two seasons. IP68 in particular must state the depth and duration, because "IP68" alone is meaningless without those agreed conditions.

5. Checklist

  • Read both digits: dust first, water second
  • Specify by real exposure and cleaning method, not the room name
  • Require the IEC 60529 test report for the exact model
  • For IP68, get the stated depth and duration in writing
  • Check the sealing method (gasket + breather) not just the number

6. FAQ

Is a higher IP always better?
No. Over-sealing traps heat and moisture: a fully sealed fixture with no breather can build internal condensation and run hotter, cutting LED life. Choose the rating the environment needs and rely on proper thermal and breather design, not the biggest number.
What does the optional letter after the IP code mean?
A trailing letter (e.g. IP66K, or an added letter like A-D/ F-M) denotes supplementary information — impact/high-pressure conditions or protection against access with specific probes. For most buyers the two digits are what matter; ask the supplier to explain any letter it adds.